久久夜色精品国产www红杏,搡老女人老妇女老熟女91精品,精品久久久无码人文字幕,懂色AV一区二区三区在线播放
簡(jiǎn)體中文 | Favorite | Member | Contribute |
You are here : 首頁(yè) > English > Products > Isotopes and Analyzers

Water Vapor Isotope Analyzer

Time:03-15,2018  Source:Los Gatos Research  Author:Cindy

WVIA 內(nèi)頁(yè).jpg

Reliable in-situ measurements of δ2H, δ17O, and δ18O in water contained in liquids, vapor, fog and clouds are important in modeling vapor dynamics and determining potential feedbacks on future climate change. In addition, fast, high-frequency isotopic water measurements provide detailed time-resolved information on the eco-physiological performance of plants and enable improved understanding of water fluxes and evapo-transpiration at ecosystem scales. These applications require rapid measurements with high accuracy and precision over a wide range of water-vapor mole fractions.

LGR’s Water Vapor Isotope Analyzer uniquely meets all of these requirements. In addition, the WVIA may be combined with LGR’s Water Vapor Isotope Standard Source (WVISS), which provides a controllable reference flow of isotopic water vapor standards. The system composed of the WVIA and WVISS provides automated, dual-inlet operation and accurate, traceable δ2H, δ17O, δ18O and water vapor mole fraction measurements without drift.

LGR’s “Enhanced Performance” models incorporate proprietary internal thermal control for ultra-stable measurements with inherently negligible drift, unsurpassed precision and highest accuracy over extremely large range of mole fractions. In addition, the availability of value-added options extends the abilities of the unit to automatically handle multiple inlets and for measurements at various locations automatically.

In response to customer demand, LGR’s WVIA is now available in the acclaimed Ultraportable package (15 kg, 65 W) for ease-of-use anywhere.

The WVIA uses LGR’s patented Off-axis ICOS technology, a fourth-generation cavity enhanced absorption technique. Off-axis ICOS has many advantages over conventional cavity ringdown spectroscopy (CRDS) techniques such as being simpler to build, operate and maintain, having a much shorter measurement time, and not requiring expensive and power consuming auxiliary components.

As with all LGR analyzers, the WVIA provides users with the entire absorption spectra and may be fully controlled remotely via the Internet. These capabilities allow the user to fully control and operate the analyzer practically anywhere Internet access is available without being on site.

Features and Benefits

Only instrument to report δ2H, δ17O, δ18O and H2O simultaneously

Automated dual-inlet operation provides unsurpassed accuracy, precision, and ease of use

Highest precision, reliable measurements at 2 Hz

High-resolution absorption spectra provide data validation and detailed system diagnostics

Now available in LGR’s Ultraportable package

Accurate measurements over an extremely wide range of mixing ratios and isotopic ratios

Proven fast flow time response allows isotopic flux studies

Enhanced Performance models provide measurements with negligible drift

Insensitive to other ambient air constituents like methane or carbon dioxide

 

Performance Specifications:

Precision (1s, 10 sec / 100 sec):

δ2H: 0.5 / 0.2

δ17O: 0.15 / 0.05 (models 911-0034, 912-0034)

δ18O: 0.15 / 0.05

[H2O]: 0.2% / 0.07%

Maximum Drift (15 min average, at STP, over 24 hrs):

δ2H: 0.8

δ17O: 0.2 (models 911-0034, 912-0034)

δ18O: 0.2

[H2O]: 0.1%

Measurement Rates:

Up to 2 Hz (up to 5 Hz, upon request)

Accuracy:

Total measurement uncertainty <0.1% (with WVISS)

Measurement Range:

4000 60000 ppm (non-condensing)

(measurements down to 100 ppm upon request)

Sampling Conditions:

Sample Temperature: -30 50 °C

Operating Temperature: 0 40 °C

Ambient Humidity: 0-100% RH, non-condensing

Outputs:

digital (RS232), Ethernet, USB

Power Requirements (steady state):

115/230 VAC, 50/60Hz, 200 watts (models 911-, 912-)

10-30 VDC, 115/230 VAC, 65 watts (model 909-0032)

Dimensions:

11” × 38” × 22 (benchtop package)

14” × 19” × 24 (rackmount package)

18.5 x 14 x 7 (portable package)

Weight:

36 kg (rackmount package)

40 kg (benchtop package)

15 kg (portable package)

 

Ordering Information (all EP models)

Part Number: WVIA-911 (δ2H, δ18O; Rackmount)

Part Number: WVIA-912 (δ2H, δ18O; Benchtop)

Part Number: TWVIA-911 (δ2H, δ17O, δ18O; Rackmount)

Part Number: TWVIA-912 (δ2H, δ17O, δ18O; Benchtop)

Part Number: U-WVIA-915 (δ2H, δ18O; portable)

 

Options

Low mole fraction operation Specify whether ranges of mole fractions will be lower than normal range

 

Accessories

908-0004-9001: Water Vapor Isotope Standard Source Provides controllable flow of water vapor at known humidity and isotope ratios for automated calibration of the WVIA

908-0003-9001: Multiport Inlet Unit Automated 16-port multiplexer

908-0003-9002: Multiport Inlet Unit Automated 8-port multiplexer

908-0008-9011: N940 Pump Provides fast flow-through times < 0.5 seconds

904-0002: Data Logging System multi-channel data logging system records and synchronizes serial (RS-232) outputs from multiple LGR analyzers and other devices (GPS, anemometers)

 

Tip
Return to Home
Home
Comment A total of comments
Username: Password:
Verification Code: Anonymous publication
Recommandations
Water Vapor Isotope Analyzer
Water Vapor Isotope
Microportable Greenhouse Gas Analyzer (CH4, CO2, H2O)
Microportable Greenh
Ultraportable CH4/CO2/H2O/NH3 Analyzer
Ultraportable CH4/CO
Deep Water Gas Analyzer
Deep Water Gas Analy
Relations
Update
Hots
ASDASD 帕納科LOS GATOS RESEARCHAMSYSIRESONONCampbellAirPhoton中國(guó)農(nóng)業(yè)科學(xué)院
久久夜色精品国产www红杏,搡老女人老妇女老熟女91精品,精品久久久无码人文字幕,懂色AV一区二区三区在线播放